VT-410 VitalCoat – Acrylic Elastomeric Coating
Product Overview
VT-410 VitalCoat is a ready-to-use, single-component acrylic elastomeric coating designed to provide flexible waterproofing and long-lasting protection for roofs and various building surfaces.
Its advanced 100% acrylic latex formulation offers excellent adhesion, flexibility, weather resistance, and resistance to fading and chalking. It helps seal hairline cracks and reduce water seepage while allowing the coating to accommodate normal expansion and contraction caused by temperature changes.
Ideal for roof maintenance, waterproofing projects, and protecting suitable construction surfaces, VT-410 VitalCoat provides a practical solution for extending roof service life.
Key Features & Benefits
Effective Waterproofing: Helps seal hairline cracks and protect surfaces against water seepage.
Excellent Flexibility: High elongation helps the coating accommodate normal surface movement.
Weather Resistant: Designed to withstand outdoor weathering.
UV Resistance: Helps resist degradation caused by ultraviolet exposure.
Fungus & Algae Resistance: Formulated to resist fungus and algae growth on the coating surface.
Strong Adhesion: Provides excellent adhesion to suitable, properly prepared substrates.
Easy Application: Can be applied using a brush, roller, spatula, or suitable airless spray equipment.
Low Odour: Water-based formulation with very low VOC content.
Versatile Application: Suitable for various roof and construction surfaces.
Recommended Applications
VT-410 VitalCoat is suitable for waterproofing, roof maintenance, and protective coating applications on compatible surfaces, including:
Concrete roofs and roof slabs
Brickwork and masonry
Cement screeds
Wood surfaces
Metal surfaces
Composite fibreboard
Foam board
Other suitable building substrates
It is particularly useful for roof surfaces where hairline cracks and water seepage are concerns.
Important: This coating is not intended for surfaces subject to heavy foot traffic, such as frequently used decks. Confirm suitability for the intended application before use.
Technical Specifications
| Property | Specification |
|---|---|
| Product Name | VT-410 VitalCoat |
| Product Type | Acrylic Elastomeric Coating |
| Appearance | Viscous liquid |
| Available Colours | White, Grey |
| Specific Gravity | 1.32 ± 0.03 |
| Solids Content | 63–66% |
| pH at 25°C | 8–9 |
| Water Solubility | Emulsifiable |
| Elongation at Break | 220% |
| Application Temperature | 5°C–40°C |
| Packaging | 1 kg, 5 kg, 20 kg pails |
| Shelf Life | 12 months, subject to proper storage |
Surface Preparation
Proper surface preparation is essential for effective coating performance.
Ensure the surface is clean, dry, and free from dust, grease, oil, and standing water.
Repair cracks wider than 4 mm using a suitable elastomeric patching compound before application.
Do not apply the coating over unsuitable or poorly prepared surfaces.
Follow the manufacturer’s latest technical instructions for substrate preparation and compatibility.
Application Instructions
Apply VT-410 VitalCoat using a brush, roller, spatula, or suitable airless spray equipment.
Apply at least two coats for the intended waterproofing application.
Allow the first coat to dry before applying the second coat at right angles to the first.
The technical data sheet specifies a dry film thickness of at least 1 mm per coat.
Allow approximately 2–3 hours of drying time between coats. Actual drying time depends on temperature, humidity, coating thickness, and airflow.
For reinforcement, glass fibre may be incorporated into the first coat while it is uncured, following the manufacturer’s instructions.
Protect the coated surface from rain and frost until fully cured. The technical data sheet recommends allowing seven days for full curing under suitable conditions.
Coverage & Consumption
The manufacturer’s technical data sheet indicates the following approximate consumption:
One coat: Approximately 1 kg/m²
Two coats: Approximately 2 kg/m²
Actual consumption may vary depending on surface porosity, texture, cracks, application method, and the required coating thickness.
Storage & Shelf Life
Store in a cool, dry place under cover.
Keep the storage temperature below 25°C.
Protect the product from freezing.
Use within the stated 12-month shelf life, subject to the manufacturer’s storage requirements.
Safety Precautions
Avoid contact with eyes, skin, and mouth.
Use in a well-ventilated area.
If the product enters the eyes, rinse immediately with water for 15 minutes and seek medical advice if irritation persists.
Keep out of reach of children.
Follow the manufacturer’s current safety instructions and product label.
Why Choose HRP Safe Zone?
At HRP Safe Zone, we aim to help customers find suitable products for roof protection, waterproofing, and building maintenance. VT-410 VitalCoat is a flexible acrylic coating option for projects requiring protection against water seepage and weather exposure.
Contact HRP Safe Zone for product availability, packaging options, and guidance on selecting the right solution for your project.
HRP Safe Zone – Solutions for Roof Protection & Waterproofing.
Dr. Fixit Pidifin 2K – Flexible Waterproofing Membrane
Product Category: Cementitious Waterproofing Membrane
Brand: Dr. Fixit
Product Name: Dr. Fixit Pidifin 2K
Available Packaging: 15/21 kg per set
Product Description
Dr. Fixit Pidifin 2K is a two-component, polymer-modified flexible cementitious waterproofing membrane specially designed for concrete and masonry surfaces. Supplied as a ready-mix kit containing two components, it forms a tough, flexible and seamless waterproof barrier when mixed and applied according to the manufacturer’s instructions.
This waterproofing solution helps protect concrete and masonry structures against water penetration and moisture-related damage.
Areas of Application
Dr. Fixit Pidifin 2K is suitable for waterproofing a wide range of concrete and masonry structures, including:
Concrete foundations and basement walls
Lift pits
Swimming pools
Water tanks and reservoirs
Concealed roofs
Parking decks
Bathrooms and toilets
Kitchens and balconies
Planters
Other concrete, cement and masonry surfaces exposed to moisture
Features and Benefits
Quick Drying: Helps reduce waiting time between application stages.
Easy Application: Can be applied using a brush or trowel.
Flexible Membrane: Forms a flexible waterproofing layer.
Excellent Adhesion: Provides adhesion to suitable concrete and masonry substrates.
Low Environmental Impact: Formulated without volatile organic compounds (VOC), according to the product data sheet.
Suitable for Damp Surfaces: Can be applied to a properly prepared damp substrate.
Waterproof Protection: The manufacturer reports no leakage under hydrostatic pressure up to 10 metres under specified test conditions.
Seamless Protection: Creates a continuous waterproof barrier when correctly applied.
Method of Application
1. Surface Preparation
Allow new concrete and masonry substrates to cure fully before application. Remove oil, grease, wax, dirt and all other contaminants that may affect adhesion. Any spalled or damaged concrete must be repaired to provide a sound substrate.
Prepare the surface to a Saturated Surface Dry (SSD) condition. The substrate should be damp but free from standing water.
2. Mixing
Using a suitable mechanical mixer, slowly add the powder component to the liquid component in a clean container. Mix until a smooth, homogeneous slurry is obtained.
Allow the mixture to stand for 5–10 minutes to release trapped air before application. Use the mixed material within the recommended pot life.
3. Application
Apply the prepared slurry evenly using a brush or trowel. Do not dilute the mixture with water.
Apply a minimum of two coats. The manufacturer’s technical data sheet specifies approximately 1.1 kg/m² per coat for a wet film thickness of about 0.8 mm. Allow the first coat to cure for at least one hour before applying the second coat.
Actual consumption may vary depending on substrate condition and application requirements.
4. Curing
For maximum protection, allow 12–24 hours of curing after the second coat.
Allow at least seven days before filling spas, swimming pools or water tanks with water, or conducting mock-up or ponding tests on site.
5. Cleaning
Clean tools and equipment with clean water immediately after use. Hardened material may require mechanical removal.
Technical Information
Mix Components: Two-component system.
Mix Ratio: 1:2 (A), as specified in the manufacturer’s technical data sheet.
Polymer Content: Greater than 18%.
Water Absorption: Less than 6%.
Proprietary Polymer: High-quality modified acrylic polymer.
Set-to-Touch Time: 45 minutes, tested according to ASTM D1640.
Tensile Strength (As Cast): 2.5 N/mm², tested according to ASTM D412.
Elongation at Break (As Cast): 60%, tested according to ASTM D412.
Adhesion to Substrate: 0.80 N/mm², tested according to ASTM D4541.
Adhesion to Concrete After 7 Days: 1.75 N/mm², tested according to ASTM D4541.
Adhesion to Concrete After 7-Day Water Immersion: 1.00 N/mm², tested according to ASTM D4541.
Crack Bridging: 1 mm, tested according to ASTM C836.
Packaging and Coverage
Product: Dr. Fixit Pidifin 2K
Packaging: 15 kg per set.
Approximate Coverage: 1–1.1 kg/m² per coat, with a minimum of two coats as specified in the technical data sheet.
Coverage depends on the surface condition, substrate porosity, application thickness and site conditions. Actual consumption may vary.
Storage
Store the product in its original, sealed container at room temperature.
Shelf Life: 12 months when stored under the conditions specified in the manufacturer’s technical data sheet.
Precautions and Limitations
Not suitable for traffic-bearing surfaces.
Supplied in pre-measured packaging.
Do not dilute with water.
Do not add additional sand or cement.
Follow the manufacturer’s mixing, application and curing instructions.
Ensure the substrate is properly prepared before application.
Health and Safety
The product is described as non-flammable in the manufacturer’s technical data sheet.
Avoid contact with skin and eyes.
If the product comes into contact with skin or eyes, wash immediately with clean water.
Wear a suitable mask during mixing.
Use protective gloves and eye protection during application.
About HRP Safe Zone
HRP Safe Zone provides information about waterproofing products and construction protection solutions to help customers make informed decisions for their building projects.
For product availability, pricing and application guidance, please contact HRP Safe Zone.
Important Note: Product specifications and application recommendations are based on the manufacturer’s technical data sheet, reference S-PI-001 Rev.EN04, dated 6 October 2016. Confirm the latest technical documentation and suitability for your project before application.
VT-442 VitalShield Flex
Flexible Cementitious Waterproofing
Product Overview
VT-442 VitalShield Flex is a two-component, polymer-modified flexible cementitious waterproofing coating designed to protect concrete and mortar surfaces against water infiltration. When mixed, it forms a smooth, brushable slurry that provides excellent adhesion to most common construction substrates.
Its flexibility helps accommodate moderate movement and hairline cracks, making it suitable for a wide range of waterproofing applications in residential, commercial, and industrial construction projects.
Key Features & Benefits
Flexible Waterproofing: Accommodates moderate movement and hairline cracks up to 1.0 mm.
Excellent Adhesion: Polymer-modified formulation enhances bonding to most substrates.
Weather Resistant: Provides good resistance to weathering for suitable exposed applications.
Breathable Coating: Allows water vapour to pass through, helping reduce vapour pressure build-up.
Easy Application: Simple mixing and application using a brush, roller, or suitable spray equipment.
Non-Toxic Formulation: The product data sheet states suitability for surfaces in contact with drinking water. Confirm the required approvals and application conditions before use.
Recommended Applications
VT-442 VitalShield Flex is suitable for waterproofing a variety of concrete and mortar surfaces, including:
Water tanks
Basements
Car parks
Terraces and balconies
Bridges and retaining walls
Swimming pools
Reinforced concrete (RC) gutters
Bathroom floors and walls
Planter boxes
Kitchens and other wet areas
Wastewater treatment plants
Shower rooms
Technical Specifications
Product Code: VT-442
Product Name: VitalShield Flex
Product Type: Two-component, polymer-modified flexible cementitious waterproofing coating
Component A: Grey premix powder
Component B: Milky liquid
Colour After Mixing: Cement grey
Specific Gravity: 1.9–2.2 (after mixing)
Solvent Content: Not present
pH at 25°C: 11–13
Tensile Strength: Greater than 0.8 N/mm²
Elongation: Greater than 75%
Shore A Hardness: Greater than 85
Crack Bridging Capability: Up to 1.0 mm
Packaging Options
7 kg Set
Component A (Powder): 5 kg
Component B (Latex): 2 kg
Packaging: 2 sets per carton
33 kg Set
Component A (Powder): 23 kg
Component B (Latex): 10 kg
Surface Preparation
Proper surface preparation is essential for effective waterproofing performance.
Remove loose plaster, dust, dirt, grease, oil, and other contaminants.
Ensure the substrate is structurally sound and free from loose particles.
Seal cracks wider than 0.7 mm appropriately before application.
Allow new concrete to cure for at least 14 days before applying the product.
Thoroughly dampen the concrete surface before application and remove any standing water.
Mixing Instructions
Use a clean container and suitable mechanical mixing equipment.
Pour approximately two-thirds of Component B (liquid) into the container.
Gradually add Component A (powder) while mixing continuously.
Mix until a smooth, lump-free paste is obtained.
Add the remaining liquid as needed to achieve a brushable consistency.
Do not add extra water to the mixture.
Mix only the quantity that can be applied within the product’s working time. Do not reuse material that has started to harden.
Application Method
Apply the mixed coating to the damp surface using a brush, roller, or suitable spray equipment.
Apply at the recommended base-coat rate of approximately 0.7–0.8 kg/m².
Allow the first coat to dry for at least 24 hours.
Apply at least two coats for effective, durable waterproofing.
Apply the second coat at right angles to the first coat, ensuring even coverage.
Follow the product manufacturer’s instructions for additional coats and site-specific conditions.
Clean tools with water immediately after use. Hardened material must be removed mechanically.
Coverage
The manufacturer’s technical data sheet specifies an approximate coverage rate of 1.5–2.0 kg/m² for a 33 kg set.
Actual coverage may vary depending on substrate condition, surface texture, application technique, and the required coating thickness.
Storage & Shelf Life
Shelf Life: 12 months under the manufacturer’s recommended storage conditions.
Storage Conditions:
Store indoors or under cover in a cool, dry place.
Keep the storage temperature at or below 30°C.
Protect the product from freezing.
Keep packaging properly sealed and protected from moisture.
Application Temperature
The product data sheet lists an application temperature range of 5°C–40°C in its product information section. A different range appears in the surface-preparation instructions. Please confirm the correct application temperature with the manufacturer before publishing this specification or applying the product.
Safety Precautions
Wear suitable protective gloves and eye protection.
Avoid breathing vapours or airborne material.
Wash hands thoroughly after handling.
Avoid direct contact with skin and eyes.
If the product enters the eyes, rinse continuously with clean water for several minutes and seek medical attention if irritation persists.
If skin irritation or a rash develops, seek medical advice.
Keep out of reach of children.
Refer to the latest Safety Data Sheet (SDS) for complete handling, first-aid, and safety information.
Important Notice
The information provided is based on the manufacturer’s technical data sheet for VT-442 VitalShield Flex, Revision No. 21-01, dated 9 November 2021.
Product performance may vary depending on site conditions, substrate preparation, application methods, and workmanship. Always consult the latest manufacturer documentation and confirm product suitability before use.
Manufacturer Information
Manufacturer: VITAL TECHNICAL SDN. BHD.
HRP Safe Zone
At HRP Safe Zone, we aim to provide clear and useful product information to help customers identify suitable construction and waterproofing solutions for their projects. Please consult the relevant technical documentation and seek professional guidance when selecting and applying waterproofing products.
VT-430 Vital SBR Latex
Carboxylated Styrene Butadiene Resin
Product Overview
VT-430 Vital SBR Latex is a high-quality waterproofing copolymer latex blended with special auxiliary chemicals. It is a water-based synthetic polymer dispersion designed to improve the workability, adhesion, strength, and durability of cement-based concrete and mortar.
This product is suitable for concrete repairs, floor toppings, rendering, plastering, waterproofing, and tile-bonding applications in the building and construction industry.
VT-430 Vital SBR Latex can also be used to improve the bonding of ceramic tiles, natural stone, marble, granite, slate, and other similar materials to concrete, plaster, concrete blocks, fibre cement sheets, particle boards, and existing ceramic tiles.
Product Specifications
Product Name: VT-430 Vital SBR Latex
Chemical Composition: Carboxylated Styrene Butadiene Resin
Appearance: Milky dispersion
Colour: White
Specific Gravity: 1.00 ± 0.02
Solid Content: Approximately 12–14%
Salt Compatibility: Excellent
pH at 25°C: 8–9
Solubility in Water: Emulsifiable
Application Temperature: 15°C–45°C
Shelf Life: 12 months
Packaging Options
VT-430 Vital SBR Latex is available in the following packaging options:
4 L pail (6 pails per carton)
18 L pail
20 L pail
Key Advantages
Ready to use from the container; simply add it to the cement mixture as required.
Significantly improves adhesion to a wide range of substrates.
Provides excellent resistance to water and water vapour when dry.
Allows thin-section applications and feather edging.
Helps reduce shrinkage.
Improves abrasion, chemical, and impact resistance.
Increases compressive, flexural, and tensile strength.
Reduces water permeability and helps protect against carbonation.
Allows a reduced water-cement ratio while maintaining equivalent workability.
Applications
1. Flooring Systems
Suitable for a wide range of flooring applications, from underlayments to heavy-duty industrial screeds.
2. Concrete Repair
Designed for general concrete repairs, patch repairs, floor repairs, old buildings, and reinforced concrete structures.
3. Primer, Bond Coats and Protective Coatings
Helps enhance the protection of structures against salts, carbonation, and mild acid exposure.
4. Waterproofing
Suitable for waterproofing applications on floors, walls, bund walls, and tanking systems.
5. Mortars and Renders
Improves adhesion, crack resistance, and weather resistance in cement-based mortars and renders.
6. Grouts
Helps improve bonding, chemical resistance, and crack resistance.
7. Tile Adhesives
Suitable for tile-bonding applications where reliable adhesion is required, including permanently wet conditions.
Surface Preparation
Proper surface preparation is essential for achieving reliable bonding and application performance.
Ensure that the surface is clean, dry, and free from dirt, grease, oil, and standing water.
Smooth substrates should preferably be mechanically roughened, grit-blasted, or needle-scrabbled to provide an adequate key for SBR-modified cementitious mixtures.
Before applying a bonding primer, dampen the concrete substrate thoroughly and remove excess water.
Application Instructions
Recommended Application Temperature: 15°C–45°C.
A. Bonding Agent and Primer
Immediately before priming, thoroughly dampen the concrete substrate with water and brush away any excess.
Apply VT-430 Vital SBR Latex using a brush or roller. The stated coverage is approximately 12 m² per 4 L.
For a cement-SBR primer, the suggested mixing ratio is 1–2 parts fresh Ordinary Portland Cement (OPC) to 1 part VT-430 Vital SBR Latex. Adjust the cement quantity as required to achieve the desired consistency.
For a cementitious base primer, the approximate coverage is 0.3–0.5 L per m² per coat. Keep the primer thickness at or below 0.5 mm to minimise the risk of cracking.
Apply the cement-based patch, render, or overlay while the primer remains tacky or wet, usually within 20 minutes, depending on site conditions.
B. Rendering and Plastering
Apply a primer coat before rendering. If a primer coat is not used, dampen the receiving surface first.
Follow the recommended mixing ratio by weight:
Cement : Fine Sand : SBR Latex = 1 : 3 : 0.45
Mix thoroughly until homogeneous, then add sufficient water to achieve the required working consistency.
Avoid adding excessive water, as it may cause rapid thinning of latex-modified mortar.
As a general guide, approximately 1.5 litres of VT-430 Vital SBR Latex will cover 1 m² at a thickness of 15 mm.
If lime is included in the mixture, it should not exceed 25% of the cement volume.
For waterproof rendering, increase the SBR Latex ratio to 0.5, as specified in the product technical data sheet.
C. Ceramic Tile, Tile and Brick-Slip Bonding Adhesive
The following suggested mixture proportions are provided in the manufacturer’s technical data sheet.
| Composition | Thin Bed (up to 3 mm) | Thick Bed (up to 12 mm) |
|---|---|---|
| Ordinary Portland Cement (OPC) | 50 | 50 |
| Clean Fine Sand (maximum size 1 mm) | 50 | 125 |
| VT-430 Vital SBR Latex | 04kg |
Application Procedure
Mix the specified components thoroughly.
Add additional water if necessary to achieve the required consistency.
Pre-dampen porous surfaces, ensuring that no free water remains on the surface.
Apply the adhesive to the back of each tile or brick slip, then press firmly into position.
Allow at least 24 hours for the adhesive to harden before filling the joints with grout.
Important: The original technical data sheet lists the proportions above without specifying measurement units. Confirm the intended units and suitability of the mixture before use.
Cleaning of Tools
Clean all tools immediately after use with water. Hardened SBR-modified cement mixtures have strong adhesion and can be difficult to remove.
For partially hardened mixtures, the manufacturer’s data sheet notes that solvents such as white spirit, used with coarse wire wool, may help with removal. Follow the relevant solvent safety instructions.
Storage and Shelf Life
Store under cover in a cool, dry place.
Keep the storage temperature below 30°C.
Protect the product from freezing.
Shelf life is 12 months under the recommended storage conditions.
VT-430 Vital SBR Latex contains sufficient bactericide to preserve the latex under normal storage conditions. If the product is diluted and stored or repacked, additional bactericide may be required.
Safety Precautions
Keep out of reach of children.
Consult the latest Safety Data Sheet (SDS) for detailed health and safety information.
Use the product according to the manufacturer’s technical recommendations.
Verify the suitability of the product and the proposed application method before use.
Technical Support and Product Information
For further product information, technical guidance, and safety documentation, consult the manufacturer’s official website:
Manufacturer: Vital Technical Sdn. Bhd.
Website: www.vitaltechnical.com
Disclaimer
The technical information presented here is based on the manufacturer’s VT-430 Vital SBR Latex Technical Data Sheet, Revision No. 20-01, dated 14 December 2020.
The information is provided as a general guide. Actual performance may vary depending on materials, workmanship, application methods, and site conditions. Users should independently verify the suitability of the product for their intended application before use.
SYNROOF HI-BUILD
Premium Quality Acrylic Waterproofing Coating
Product Overview
BITUMAT SYNROOF HI-BUILD is a premium-quality elastomeric acrylic waterproofing coating designed for roof waterproofing applications. It can be applied using a soft brush, roller, squeegee or suitable spray equipment, depending on site conditions.
The product forms a flexible waterproofing membrane and is suitable for various roof surfaces when properly prepared and primed.
Key Features
Premium-quality elastomeric acrylic waterproofing coating
Suitable for brush, roller, squeegee and spray application
Flexible coating with a reported elongation at break of 440%
UV resistance tested for 2,000 hours
Suitable for a range of roof substrates with appropriate surface preparation
Available in Satin White and Grey; other colours available on request
Can be reinforced with polyester mesh where additional reinforcement is required
Recommended Applications
SYNROOF HI-BUILD may be used on the following roof surfaces, subject to proper preparation and priming:
Concrete and cementitious roofs
Terrazo tile roofs
Metal roofs
Old asphalt surfaces
Bituminous roofing felt
Other suitable roof surfaces requiring waterproofing treatment
Surface Preparation
Proper surface preparation is essential for the performance and durability of the waterproofing system.
Ensure the surface is smooth, clean and completely dry.
Remove dust, dirt, rust, loose paint, oil and other contaminants.
Concrete and cementitious surfaces must be well compacted, at least 28 days old and thoroughly dried.
Wooden and metal panels must be firmly fixed in position.
Clean terrazo roof tiles and repair damaged joints. Ensure the tiles are firmly grouted.
Remove moss, mildew, loose paint and rust from metal roofs before priming.
Repair and prepare existing asphalt or bituminous roofing surfaces before application.
Priming Instructions
Select the appropriate primer preparation according to the roof substrate.
Old Asphalt Surfaces and Bituminous Roofing Felt: Cut blistered roofing felt crosswise, dry it and re-bond it using a suitable adhesive. Allow it to cure, then apply SYNROOF HI-BUILD diluted with 20% water as the primer.
Concrete and Terrazo Tile Roofs: Remove all loose material and contaminants. Apply SYNROOF HI-BUILD diluted with 20% water. Excessive dilution may weaken adhesion.
Metal Roofs: Remove rust and apply a suitable rust-inhibitive metal primer to the affected surfaces.
Other Roof Surfaces: Remove algae and fungal growth using a stiff-bristled broom. Treat the cleaned surface with a suitable fungicide, then apply a primer coat of SYNROOF HI-BUILD diluted with 20% water.
Allow the primer to dry completely before applying the waterproofing coats.
Application Method
Ensure the prepared surface and primer are completely dry.
Apply SYNROOF HI-BUILD using a soft brush, roller or suitable spray gun.
If spraying is required, use suitable equipment and a nozzle of at least 0.028 inch. Slight dilution with water may be used where necessary.
Apply two coats at an approximate application rate of 0.8 kg/m² per coat, excluding the primer coat.
Apply each coat at right angles to the previous coat to help achieve consistent coverage.
For roofs requiring additional reinforcement, use 60–80 gsm thermally bonded polyester mesh as part of a sandwich membrane system. Embed the mesh in the wet first coat before applying subsequent coats.
Reinforce details around pipes, upstands, drains and other projections where required.
The final dry film thickness may be built up between 0.5 mm and 1.5 mm, depending on the requirements of the roof.
Curing Time
Touch-dry time: Approximately 8 hours at 25°C.
Time between coats: Allow 24 hours.
Final curing: Approximately 48 hours at normal working temperatures, as stated in the application instructions.
Low temperatures and high humidity may slow the curing process. Ensure the coating has fully cured before installing insulation boards, mechanical protection or other coverings.
Mechanical Protection
Accessible Roofs: Protect the waterproofing membrane with a suitable separation layer, followed by appropriate thermal insulation where required. A protective screed of approximately 4–5 cm or suitable cement tiles may be used as described in the product instructions.
Non-Accessible Roofs: Install a non-woven polyester separation layer over the waterproofing membrane, followed by insulation boards where required. Add a further separation layer above the insulation and cover with washed gravel to a minimum depth of 5 cm. For thicker insulation boards, the gravel depth should be at least equal to the board thickness.
Technical Data
| Property | Typical Value | Test Method |
|---|---|---|
| Solids Content | 64 ± 1% | ASTM D1076 |
| Viscosity | 50,000–70,000 CPS | Brookfield |
| Density | 1.30 ± 0.05 kg/L | ASTM D1475 |
| Minimum Application Temperature | +5°C | In-house test |
| Touch-Dry Time at 25°C | Approximately 8 hours | In-house test |
| Service Temperature | Approximately -5°C to 100°C | In-house test |
| Tensile Strength | 480 N/cm² | ASTM D412 |
| Elongation at Break | 440% | ASTM D412 |
| Hardness | 68 Shore A | ASTM D2240 |
| Permeability | Pass | ASTM E398 |
| Dry Peel Adhesion | 65 lb/in² | ASTM C297 |
| Flexibility | No cracking after 1,000 hours of accelerated weathering and 180° flexing | In-house test |
| UV Resistance | 2,000 hours; no deterioration or colour fading reported | ASTM D822 |
| Colours | Satin White and Grey; other colours on request | — |
| Coverage | Approximately 2 kg/m² for a 1 mm dry film | — |
Note: Technical values are typical values reported in the manufacturer’s technical data sheet. Actual performance and consumption may vary depending on substrate condition, application method and site conditions.
Coverage and Consumption
The technical data sheet specifies an approximate consumption of 2 kg/m² for a 1 mm dry film thickness.
The application instructions also recommend two coats at approximately 0.8 kg/m² per coat, excluding primer. Actual coverage depends on surface texture, substrate condition, required film thickness and application method.
Precautions
Ensure bitumen and asphalt surfaces are completely dry before application.
Do not apply when rain is imminent.
Avoid applying thick coats at temperatures below +5°C, as this may affect film formation and flexibility.
The cured coating is resistant to light foot traffic only. Protect it against heavy traffic, high-heel shoes, furniture and other sources of mechanical damage.
Do not use the product in areas that remain continuously submerged in water.
Do not clean the cured coating with hard-bristled brooms.
Follow the recommended application, curing and protection procedures.
Cleaning
Clean hoses, equipment and application tools with water immediately after use. Wet material can be removed with water; a suitable proprietary hand cleaner may be used for dried material.
Packaging
Standard packaging: 20 kg metal pails.
Other packaging options may be available on request.
Storage and Shelf Life
Store away from direct sunlight.
Recommended storage temperature: Above +5°C and below 30°C.
Protect the product from frost.
Minimum shelf life: One year in unopened containers, as stated in the technical data sheet.
Health and Safety
The product is described in the technical data sheet as non-toxic and odourless.
It is non-flammable when wet; the cured film will burn but is not described as a fire hazard.
Avoid prolonged skin contact. Gloves or a suitable barrier cream are recommended for sensitive skin.
If the product comes into contact with the eyes, rinse thoroughly with clean water and seek medical assistance.
Seek medical assistance if the product is swallowed.
Adequate ventilation in the working area is desirable.
Important Notice
The technical information presented here is based on the manufacturer’s product data sheet and represents typical values obtained through laboratory testing and practical experience. Actual results may vary depending on application conditions and factors beyond the manufacturer’s control.
For the best results, follow the manufacturer’s current technical instructions and ensure that the roof surface is properly prepared before application.
Product Name: SYNROOF HI-BUILD
Product Type: Acrylic Waterproofing Coating
Brand: BITUMAT
Website: HRP Safe Zone
Fosroc Nitobond SBR
Water-Resistant Polymer Additive & Concrete Bonding Agent
Product Overview
Fosroc Nitobond SBR is a modified styrene-butadiene rubber (SBR) emulsion supplied as a ready-to-use white liquid. It is designed to improve the bonding, strength, workability and water resistance of cement-based mortars, concrete repair materials, floor screeds and renders.
It is suitable for a wide range of internal and external construction applications, helping improve adhesion and durability when used in accordance with the manufacturer’s recommendations.
Key Features & Benefits
Excellent Bonding: Improves adhesion to concrete, masonry, stonework, plaster and blockwork.
Enhanced Strength: Improves the tensile and flexural properties of cementitious mortars.
Improved Workability: Enhances cohesion and makes mortar easier to handle and apply.
Water Resistance: Helps produce water-resistant concrete repairs, renders and floor toppings.
Reduced Permeability: Helps reduce the penetration of water and certain aggressive substances.
Versatile Application: Suitable for horizontal, vertical and overhead concrete repair work.
Easy to Use: Single-component liquid that can be measured and mixed as required.
Applications
Fosroc Nitobond SBR is suitable for:
Concrete repair mortars
Cementitious floor toppings and screeds
Waterproof cement-based renders
Cementitious bonding slurries
Tile-bonding mortars
Internal and external cement-based repair work
Horizontal, vertical and overhead repairs
Technical Specifications
Product Name: Fosroc Nitobond SBR
Product Type: SBR polymer emulsion and bonding agent
Appearance: White liquid
Base: Modified styrene-butadiene rubber emulsion
Compressive Strength: 62 MPa
Tensile Strength: 3.3 MPa
Flexural Strength: 9 MPa
Slant Shear Bond Strength: 53 MPa
VOC Content: 29 g/litre
Recommended Application Thickness: Generally 6–40 mm, depending on the application and repair configuration.
Packaging: 20-litre container listed in the manufacturer’s technical data sheet.
Note: The mechanical strength values were obtained from a 3:1 sand-to-cement mortar containing 4 litres of Nitobond SBR per 20 kg of cement, tested at 28 days under air-cured conditions. Actual results depend on the mix design, substrate and site conditions.
Typical Mix Designs
The following mix proportions are taken from the manufacturer’s Technical Data Sheet. Water quantities may require adjustment according to the moisture content of the sand and aggregate.
1. Concrete Patching & Repair Mortar
General-purpose cement: 20 kg
Grade 16/30 sharp sand: 60 kg
Nitobond SBR: 4 litres
Clean water: Approximately 3 litres
Approximate yield: 38 litres
Recommended thickness: 6–40 mm
2. Heavy-Duty Floor Screed
General-purpose cement: 20 kg
Crushed rock, 3–6 mm: 30 kg
Grade 16/30 sharp sand: 30 kg
Nitobond SBR: 2.5 litres
Clean water: Approximately 2.5 litres
Approximate yield: 37 litres
Recommended thickness: 10–40 mm
The screed should have a semi-dry, cohesive consistency.
3. Cement-Based Render
General-purpose cement: 20 kg
Grade 16/30 sharp sand: 60 kg
Nitobond SBR: 2.5 litres
Clean water: Approximately 2.5 litres
Approximate yield: 37 litres
Recommended thickness: 6–9 mm
4. Bonding Mortar for Tiles and Similar Applications
General-purpose cement: 20 kg
Grade 16/30 sharp sand: 50 kg
Nitobond SBR: 4 litres
Clean water: Approximately 3 litres
Approximate yield: 33 litres
Recommended thickness: 6–40 mm
Adjust the water quantity to achieve a firm mortar consistency and provide support where necessary until the mortar sets.
Application Guidelines
Surface Preparation
Prepare the concrete surface by removing dust, loose materials, oil, grease, paint and other contaminants. Repair edges should be properly cut back to avoid feather-edged repairs. Remove corrosion deposits from exposed reinforcement and prepare the steel appropriately.
Substrate Priming
Thoroughly soak the substrate with clean water and remove excess water before priming.
Prepare a slurry primer using:
1 volume Nitobond SBR
1 volume clean water
3 volumes fresh cement
Mix to a smooth consistency and work the slurry well into the concrete surface. Apply the repair mortar, topping or render while the primer remains wet. If the primer dries, remove it and re-prime the surface before proceeding.
Mixing
Use a suitable forced-action mixer. Dry-blend the cement, sand and aggregate before adding the pre-mixed Nitobond SBR and clean water. Mix thoroughly to achieve a smooth, homogeneous consistency. Keep additional water to a minimum and account for moisture in the aggregates.
Application
Apply the mortar to the primed substrate and compact it properly using a trowel. Ensure exposed reinforcement is fully covered by the repair mortar.
The usual minimum application thickness is 6 mm. Maximum thickness depends on the location and configuration of the repair. If sagging occurs, remove the affected section and reapply it correctly.
Finishing & Curing
Finish the surface with a suitable steel, plastic or wood float, or use a damp sponge where appropriate. Avoid overworking the surface.
Cure cement-based materials immediately after finishing in accordance with good concrete practice. In harsh drying conditions, additional protection such as polythene sheeting may be required.
Coverage & Yield
Nitobond SBR as a slurry primer: Approximately 2–3 m² per litre.
Coverage is theoretical and may vary depending on surface conditions, wastage, substrate porosity and the mix design used.
For mortar and screed yields, refer to the typical mix designs above.
Storage & Handling
Store in a dry place in the original, unopened packaging.
Protect the product from frost.
In cold conditions down to 5°C, the manufacturer recommends considering warm mixing water up to 30°C.
At ambient temperatures above 35°C, store the material in the shade and use cool mixing water.
Clean tools, equipment and mixers with clean water immediately after use. Hardened material can only be removed mechanically.
Important Application Limitations
Do not apply Nitobond SBR mortars, toppings or renders when the temperature is 5°C and falling.
Do not expose the material to moving water during application.
Heavy rainfall before the final set may damage the surface.
Application thickness, mix proportions and performance may vary with site conditions.
Always consult the latest manufacturer’s Technical Data Sheet (TDS) and Safety Data Sheet (SDS) before use.
Why Choose Fosroc Nitobond SBR?
Fosroc Nitobond SBR is designed to improve the adhesion, workability and performance of cement-based construction materials. It offers a versatile solution for concrete repairs, floor screeds, renders and bonding applications when used with the correct preparation, mixing and curing procedures.
HRP Safe Zone provides product information to help construction professionals and customers identify suitable construction materials for their projects.
Product Information: For detailed technical guidance, consult the manufacturer’s latest documentation or contact the product supplier.